Contact Us

1970 Miller big 40 will start up but won't weld any

My 1970 Miller big 40 will start up and run but won't weld now. Just got done doing some work to the motor but didn't really touch the generator side of it except that I put a new range selector switch in it. Not sure what's wrong was welding before got the switch with the welder old 1

Miller Big 40 won't weld no AC WeldingWeb

2018-6-20  Re: Miller Big 40 won't weld no AC I pointed it out as one can use any appropriate DC voltage source to test a generator (technically an alternator) for output. I routinely use a 115VAC-to-12VDC power source, 18V cordless tool battery or 12V automotive batter to

MILLER ELECTRIC BIG 40G OWNER'S MANUAL Pdf

Miller electric owner's manual welding engine driven welding generator big blue 402d, big blue 502d, big blue 602dr (116 pages)

big 40 miller American Welding Society

2007-10-24  The Big 40 has a bridge rectifier (2" x 2" black square with 4 spade terminals) located on right side of control panel, that is used to exciter the circuit. No weld or 110 = look at slip rings and brushes, bridge rectifier and resistor. Check faulty connections or faulty parts. Or loss of residual magnetism you may need to 'flash' field.

How to Troubleshoot Miller Welders Our Pastimes

Miller Welding is a company that specializes in welding equipment, from MIG, or metal inert gas, welders to stick welders. When they are in working order, they are effective welding units for home or retail purposes. However, potential problems could range from

Miller Electric Big 40 Engine Drive Welder

2012-12-31  A discussion of Engine Drive welders would not be complete without talking a bit about a classic engine drive welder, the Miller Big 40. This Model has been around for years, but what it stands for has changed. Ours is a 1979 model and far from the oldest 'Big 40' on the planet.

Description Big Blue 401DX Miller Welding Equipment

2019-11-13  Do not weld where flying sparks can strike flammable material. Remove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers. Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.

Re: miller big 20 won't strike arc -- The Welding Forum

If not, we need to check the exciter in the unit. Your unit is equipped with a belt driven alternator that supplies power to the main field of the generator. This alternator is located on the top of the main welding generator. The alternator relies on battery voltage that we supply to

Frequently Asked Questions FAQs Miller Welding

The Multimatic 215 is not capable of AC TIG welding. For an inverter power source to have AC TIG welding capabilities, it must be able to carry weld current in both AC and DC modes, which requires additional components and design considerations. We do offer a new machine that has both AC and DC TIG capabilities, Multimatic 220 AC/DC.

1970,1980 miller big20,big40 American Welding

2010-11-7  Topic Welding Industry / General Welding Discussion / 1970,1980 miller big20,big40 By silentscream Date 11-06-2010 05:14 i am wanting to get into pipeline work but was wanting opinions on old 1970's,1980's miller big 20,big 40 any advice would be great thank you

big 40 miller American Welding Society

2007-10-24  The Big 40 has a bridge rectifier (2" x 2" black square with 4 spade terminals) located on right side of control panel, that is used to exciter the circuit. No weld or 110 = look at slip rings and brushes, bridge rectifier and resistor. Check faulty connections or faulty parts. Or loss of residual magnetism you may need to 'flash' field.

Miller Big 40 Welder output issues Smokstak®

2019-3-24  We have a 1979 Miller Big 40 that has some issues In order to get it to weld properly, we need to have the amperage control maxed out, and even then the beads are too cold. I noticed while the welder is being used, one of the big resisters at the back of the machine is glowing red; right up to the adjustment collar.

Miller Big 40 Welder TractorByNet

Miller Big 40 Welder Searched but no luck, was probably doing it wrong. Welder has been sitting for a while, got the Red Seal gas engine running good but no power from the generator. So far I've cleaned the slip rings and brushes, still nothing on the volt meter. Looked for

How to Troubleshoot Miller Welders Our Pastimes

Miller Welding is a company that specializes in welding equipment, from MIG, or metal inert gas, welders to stick welders. When they are in working order, they are effective welding units for home or retail purposes. However, potential problems could range from

Miller Electric Big 40 Engine Drive Welder

2012-12-31  A discussion of Engine Drive welders would not be complete without talking a bit about a classic engine drive welder, the Miller Big 40. This Model has been around for years, but what it stands for has changed. Ours is a 1979 model and far from the oldest 'Big 40' on the planet.

MILLER ELECTRIC BIG BLUE 402D OWNER'S MANUAL

View and Download Miller Electric Big Blue 402D owner's manual online. Miller Electric Owner's Manual Welding Engine Driven Welding Generator Big Blue 402D, Big Blue 502D, Big Blue 602DR. Big Blue 402D welding system pdf manual download. Also for: Big blue 502d, Big blue 602dr.

I have a miller big blue 400 diesel driven welder. It

I have a miller big blue 400 diesel driven welder. It starts,runs,output receps work but does not weld, what could be wrong it only has 1750 hours on it. I also bought it at an auction but it was working then.

1990 Miller Big 40G Portable Welder/Generator On

1990 Miller Big 40G Portable Welder/Generator On Trailer, 661 Hrs Showing, Asset #903043, 64" Length, 24" Width, 40" Height, Generator Output: 120/240, 26/13 Amps, 3 KW, DC Welder Output Max Voltage 95, Volts 34, 32, Weld Range 50-440 Amps, 3 Cylinder Continental Gas Engine Model TW20, Block Heater, Reversible Air Intake For Winter Operation, Mounted On Shop Made Trailer: 77" Wide X 11'-8

MILLER BIG 20?? American Welding Society

2008-6-24  I believe it should rev up to 1800 rpm with the auto idle switch in the on position. At the miller website ( millerwelds ) under the resourses tab ,owners manual,you can find and download the original owners manual that came with the big 20. There is a troubleshooting guide in there.

Miller Rheostats and Potentiometers Page 1 of 1

2019-2-11  Miller engine drives units: Big 20, Big 40, Big 50, Trailblazer & many more. Two Year Warranty. PLEASE CHECK THE OHM & WATTS BEFORE ORDERING PART NUMBER SUPERCEDES 207177. Quantity 605960 300 WATTS/34 OHMS Rheostat $283.34 605960.

Miller Big 40 Welder output issues Smokstak®

2019-3-24  We have a 1979 Miller Big 40 that has some issues In order to get it to weld properly, we need to have the amperage control maxed out, and even then the beads are too cold. I noticed while the welder is being used, one of the big resisters at the back of the machine is glowing red; right up to the adjustment collar.

Miller Big 40 Welder TractorByNet

Miller Big 40 Welder Searched but no luck, was probably doing it wrong. Welder has been sitting for a while, got the Red Seal gas engine running good but no power from the generator. So far I've cleaned the slip rings and brushes, still nothing on the volt meter. Looked for

Miller Electric Big 40 User Manual

Big 40 ® Diesel CC Specifications (Subject to change without notice.) Welding. Weld Output. Weld Output Rated Max. Open- Generator Output Rated Net Weight. Mode. Range. at 104˚F (40˚C) Circuit Voltage at 104˚F (40˚C) Dimensions ** (without fuel) *** CC/DC. 55 500 A

SA200 vs Miller Big 40 Weld Talk Message Boards

These yards make big industrial components in secions for syncrude and the like. You gotta figure that companies make 1/4" rod for something, those that don't roll pipe are running 3/16" Alot of welded pipe, and we are talking oil related, is rolled, We have procedures call for the big rod, I've read the requirements so piss off.

How to Troubleshoot a Miller Welder 1E Home

2017-7-21  Miller has manufactured welders since 1929, and you can find its units throughout the world. Problems that may occur include low or no weld output, dirty spark plugs and air filters, and low power

1990 Miller Big 40G Portable Welder/Generator On

1990 Miller Big 40G Portable Welder/Generator On Trailer, 661 Hrs Showing, Asset #903043, 64" Length, 24" Width, 40" Height, Generator Output: 120/240, 26/13 Amps, 3 KW, DC Welder Output Max Voltage 95, Volts 34, 32, Weld Range 50-440 Amps, 3 Cylinder Continental Gas Engine Model TW20, Block Heater, Reversible Air Intake For Winter Operation, Mounted On Shop Made Trailer: 77" Wide X 11'-8

Reactor in a portable Miller Big 40 welder? Terry

2009-11-3  A Big 40 is usually a Continental 4 cylinder engine driven welder. All Miller welders produce AC weld output and use a rectifier for DC weld output. The rectifier on one of those is maybe an arrangement of stud diodes mounted on the endplate or more likely a set of diodes mounted in a grid of flat plates as a complete unit.

Buy Miller Welder Parts online from Weldfabulous

Miller Electric. Miller 196575 Switch, Rocker Spst 10A 250Vac On-None-Off .250 Qc

i have a air product dc300wge it will not weld, when

i have a air product dc300wge dc welder but looks like a miller big blue it will not weld, when you strike an ark it just will spark but just very little and it does not rev the engine i have to manually do it. but the ac outlet does work it puts out 126v ac. i just purchased this welder and was told that it worked when it was pulled off the welding truck. i am thinking that the generator does

Miller Rheostats and Potentiometers Page 1 of 1

2019-2-11  Miller engine drives units: Big 20, Big 40, Big 50, Trailblazer & many more. Two Year Warranty. PLEASE CHECK THE OHM & WATTS BEFORE ORDERING PART NUMBER SUPERCEDES 207177. Quantity 605960 300 WATTS/34 OHMS Rheostat $283.34 605960.